Favorable Outcomes With Machine Perfusion and Longer Pump Times in Kidney Transplantation
A Single-Center, Observational Study.
Hypothermic machine perfusion (MP) preservation is used for all deceased donor kidney transplants at our center. Kidneys are placed in cold storage at retrieval, then transferred to MP on arrival. Because a lack of consensus regarding optimal use of MP still exists, we evaluated the overall impact of using MP at our center and the prognostic value of MP (Pump) time.
Methods. We retrospectively analyzed 339 adult, primary deceased donor kidney transplant recipients who were pooled across three prospective, randomized immunosuppression trials (since 2000) at our center. In addition to providing overall results for delayed graft function (DGF) (requirement for dialysis in the first week), slow graft function (SGF), first biopsy-proven acute rejection (BPAR), and graft failure, stepwise logistic and Cox regression analyses were used to determine the prognostic value of pump time, particularly after controlling for other significant prognosticators.